HNB2L 6KA 30mA Remote Control Circuit Breaker Suppliers

HNB2L

HNB2L-63 Type Residual Current circuit breaker (RCCB)(without overcurrent protection)ensure electrical safety in homes and similar situations, such as offices and other buildings as well as for industrial applications by protecting electrical installations against leakage Current reach to 30mA. Once a fault is detected, the Residual Current circuit breaker automatically switches off the electrical circuit to prevent risk to the people. Warranting reliability and safety for people and assets.

Additional information

Share To:

Product Advantages

Operating mechanism is plastic structure, operating performance is more stable and reliable than metal structure. such as release force, mechanical life cycle.For environmental protection is better than metal type and also the type is new generation mechanism.

All screws are with the plastic cover seal the holes,lt’s move safety can not open the products in easy.

A Big sizes transparent signboard can help user make some special marks in the signboard area.

The very new tripping structure make more safety

Cambered cover and handle make the operation be more comfortable and appearance be more beautiful.

Protect the circuit under the condition of overload, and the handle is tripped and stopped at the middle position, so as to repair the circuit with fault  quickly. The handle cannot be stopped at the position during manual operation.

lt has earthing fault, electric leakage and isolation and protection function.

It is equipped with finger-protection wiring terminal.

The shell and components are made of high flame resisting, high temperature resisting and impact resisting engineering plastic.

lf the current of earthing fault or electric leakage exceeds the stipulated value, the circuit will be cut off automatically.

The dynamic and wire pressure are independent and are not affected by external disturbance and voltage fluctuation.

Product Parameter (Specification)

StandardIEN61008-1 IEN62423
TypeElectronic type (Auxiliary Electromagnetic type)
Characteristics of residual operation currentand B
Poles1P+N,3P+N
Rated operating break capability10 InA
Rated current (A)25,40,63
Rated voltageAC 240/415
Rated frequency50/60 HZ
Rated residual operation current I△n (A)0.03, 0.1 and 0.3
Rated residual non-operating current I△nno0.5I△n
Rated limited short circuit current10 KA
Rated limited residual short circuit current l△c10 kA
Scope of residual operating current0.51△n~I△n
Wiring height19 mm
Mechanical electrical life4,000 cycles
Wiring section area of terminalconductor of 25 mm² and below
Wiring terminalscrew terminal
Wiring methodcolumn type wiring method
Tightening torque2.0Nm
InstallationInstallation of 35.5mm guide rail /  Vertical installation
Enclosure protection classIP20

Basic Parameters

Rated current
of housing
grade In m(A)
PolesFrequency (Hz)Rated voltage
Ue(V)
Rated current
In(A)
Rated residual
current(A)
Rated limited
short circuit
current Inc(A)
Rated limited
residual short
circuit current
I△C(A)
631P+N50/60Hz24025 40 630.03 0.1 0.31000010000
3P+N415

Standard value of breaking time and non-operating time for pulse DC residual current and smooth DC residual current produced by rectifying circuit

TypeIn(A)I△n(A)Standard value of breaking time and non-operating time for equality of residual.
current (I△A ) and following values (S)
General typeAny valueAny value2 I△n0.310 I△n5A,10A,20A,50A,100A,200A
0.30.150.040.04

Range of tripping current(Table 1)

ModelTripping  current I△ /A
AC0.5 I△n<I△n
AAngle of retardI△n>0.01AI△n<0.01A
0.35I△n≤I△≤1.4I△n0.35I△n≤I△≤2I△n
90°0.25I△n≤I△≤1.4I△n0.25I△n≤I△≤2I△n
135°0.1I△n≤I△≤1.4I△n0.1I△n≤I△≤2I△n

Different from (B type) of 50/60 Hz as per frequency(Table 2)

Residual operating currentResidual operating currentResidual operating current
1500.5I△n2.4I△n
4000.5I△n6I△n
1000I△n14I△n

Tripping scope as per smooth DC residual current (type B shall meet following requirements on the premise of type A)

For sinusoidal AC residual current no more than 1000Hz, the trip current range between diferent frequencies according to the requirements of Table 2.With a sudden residual trip current in Table 2, the breaking time should be no more than 0.3s,The minimum no trip time of type S should be no less than 0.13s, and the maximum breaking time should not exceed 0.5s.

lf smooth residual current 0.4 time rated residual operation current (I△n) or 10 mA smooth DC residual current (the bigger shall prevail) is overlapoed on the rated frequency AC residual current. type B RCCB shall be operated. and the AC trippind current shall be no more than l△n.

If smooth DC residua current 0.4 tme rated residual operation current (I△n) or 10 mA smooth DC residua current (the biocer shaprevai) is overlapped on the pulse DC residual current. type B RCCB shall be operated. The tripping current of RCCB with l△n > 0.01A shall be no more than 1.4 l△n while the tripping current of RCCB with l△n≤0.01 A shall be no more than 2l△n.

For the pulse DC residual current which is stably increased and produced by two relative rectifying circuits, type B RCCB shall be actuated within the scope of 0.5 l△n to 22 1△n Type B shall trip within the time range specified according to the Table 1,With a sudden pulsating DC residual current applied to the rectifier circuit.

For the pulse DC residual current which is stably increased and produced by three relative rectifying circuits, type B RCCB shall be operated within the scope of 0.5 l△n to 22 1△n Type B shall trip within the time range specifed according to the Table 1,With a sudden pulsating DC residual current applied to the rectifier circuit.

For the smooth DC residual current which is stably increased, type B RCCB shall be operated within the scope of 0.5 l△n to 22 1△n Type B shall trip within the time range specifed according to the Table 1.With a smooth DC residual current applied to the rectifier circuit.

According to the Table 3, composit wave and initial value provided in steady.RCCB composite wave residual current range of 0.5I△n to 1.4 1△n, Sudden application of 71△n,Normally the RCCB break time should be less than 0.04s, Type S RCCB break time should be less than 0.15s.

The component values of different frequencies in the test current & the verified correct initial value when theresidual current is increased steadily(Table 3)

The component values of different frequencies in the test current (RMS)The verified correct initial
value (RMS)
Rated FrequencyI 1kHzI FMotor  (10Hz)I △
0.138I△n0.138I△n0.035I△n0.2I△n

 

message

Online Message

If you have any needs , please fill out the form below and we will contact you as soon as possible.

Related Products

View similar products to find what you want.

Single-phase electronic rail-type active energy meter

Single-phase

QJSPD-PV40

DZ47-63

Get In Touch With Us

We’re here to help! Whether you have questions, need assistance, or want to learn more about our products and services.